Adaptive Tunnel Lighting System

STSYSTEMPLC engineers an industrial-grade Tunnel Lighting System for approach, portal, threshold, transition, interior and exit zones. The control chain can connect portal luminance sensors, traffic inputs, CH-800 edge gateways, interconnected intelligent lighting cabinets, circuit controllers and SLC810/SLC910 lamp-level controllers.

The Tunnel Lighting Control System coordinates approved luminance curves, dimming ramps and project-configured 2700K–6000K Adaptive CCT according to exterior luminance, traffic conditions, weather and operating modes. Approved local schedules, safety scenes and manual authority can remain available during central-platform or WAN loss.

Adaptive Tunnel Lighting and Tunnel Entrance Lighting must be designed from tunnel geometry, portal orientation, pavement, luminaire optics, design speed, sensor location and applicable standards. Required zone lengths, lighting curves, transition behavior and acceptance measurements are confirmed for the selected project configuration.

For qualified strategic partners, STSYSTEMPLC can support Partner-Branded Solution Packaging and Owner-Controlled Deployment for Security-Sensitive Infrastructure Projects.

STSYSTEMPLC engineers an industrial-grade Tunnel Lighting System with Adaptive Control for Portal Safety for adaptive tunnel portal lighting, connecting portal luminance zones, traffic sensing, dimming curves and safe fallback scenes into a controlled owner-side operating model.

Hybrid PLC, LoRA, NB-IoT, CAT-1, Ethernet or fiber communications can be selected by project layout, distance, cabinet position, cellular coverage and owner hosting policy. Black-hole and white-hole mitigation can be organized by asset name, zone, alarm priority, maintenance responsibility and commissioning batch.

Schedules, sensing logic, local fallback behavior, alarm handling and Factory Test & Site Commissioning support controlled deployment from pilot section to phased rollout and lifecycle handover.

For qualified strategic partners, STSYSTEMPLC can support Partner-Branded Solution Packaging and Owner-Controlled Deployment for Security-Sensitive Infrastructure Projects.

STSYSTEMPLC IoT Tunnel Lighting Engineering

Human-Centric Adaptive Tunnel Lighting for Black-Hole and White-Hole Mitigation, Visual Adaptation and Entrance-Exit Safety

Engineer a human-centric adaptive tunnel lighting system through interconnected intelligent lighting cabinets, direction-specific lighting zones, black-hole and white-hole mitigation, traffic-responsive dimming, entrance and exit adaptation and local control continuity—giving tunnel operators a coordinated, measurable path from visual-safety requirements to FAT, SAT and field acceptance.

Tunnel Lighting System Tunnel Lighting Control System Adaptive Tunnel Lighting Tunnel Entrance Lighting Black Hole Effect Tunnel Lighting Human-Centric Tunnel Lighting

TUNNEL LIGHTING SOLUTION VIDEO

Adaptive Tunnel Lighting System, Portal Control and Visual Transition

SYSTEM OVERVIEW

What Is a Tunnel Lighting System with Adaptive Control?

A tunnel lighting system coordinates portal luminance sensing, traffic inputs, approved zone curves, interconnected intelligent lighting cabinets, circuits and lamp-level execution across approach, threshold, transition, interior and exit zones. It supports gradual visual adaptation, project-configured CCT, local fallback, manual authority and controlled recovery during central-platform or communication loss.

Procurement decision: verify this definition against the offered topology, configured limits, verified device status, abnormal cases and owner-held recovery evidence before wider deployment.

ENGINEERING SUMMARY

What Should Owners Understand before Technical Approval?

The solution begins with direction-specific portal conditions, tunnel geometry, design speed, pavement, luminaire optics and approved luminance targets. Exterior luminance and traffic inputs are validated before selecting a permitted curve for approach, threshold, transition, interior and exit zones. CH-800 edge gateways and intelligent cabinets hold local schedules, minimum scenes and recovery rules so the tunnel does not depend on continuous WAN availability. Circuit and lamp-level commands should be compared with actual field states, alarms and timestamps. Adaptive CCT may be used only where the selected luminaires, visual design and owner policy support it. Approval should witness daytime, nighttime, rapid-light-change, sensor-error, network-loss, manual-control and reconnection cases, together with field luminance measurements and owner-held configuration records.

PROJECT FIT, INTEGRATION AND RESPONSIBILITY

Where Does This Adaptive Tunnel Lighting Solution Fit?

Who Should Use It?

Highway authorities, tunnel operators, design institutes, electromechanical EPC teams, lighting designers and long-term operation and maintenance teams.

Which Projects Fit?

Highway, mountain, urban, subsea and long tunnels where portal luminance, traffic, weather or operating modes require coordinated zone control.

When Is It Not the Right Scope?

Short, low-speed tunnels where a verified fixed scene already meets the required visual and operating criteria and networked adaptation adds no justified value.

How Does It Integrate?

Define sensing, power, communication, zone ownership, command priority, manual control, timeout, fallback and third-party interfaces before commissioning.

How Can Existing Assets Be Retained?

Survey cabinets, circuits, luminaires, drivers, sensors and communication routes. Reuse only assets qualified through compatibility tests and a documented rollback route.

How Is Long-Term Operation Protected?

Keep owner access to zone curves, permissions, calibration records, configurations, alarms, backups, compatible spares and tested restoration procedures.

Project boundary: luminance levels, zone lengths, CCT, control curves and interfaces are configured according to the tunnel design, local regulations, owner requirements and the written acceptance plan. No site-independent lighting level or universal interface package is implied.

FIELD EVIDENCE FOR HIGHWAY AND TUNNEL PROJECTS

Which Operating Views Support Technical Evaluation?

93 km Smart Highway and Tunnel Lighting Deployment

Review corridor zoning, intelligent cabinets, communication routes and the relationship between roadway, portal and tunnel lighting operations.

Adaptive CCT under Rain, Fog and Snow Conditions

Review how project-configured CCT scenes can be coordinated with measured conditions, local authority and approved transition rules.

Evidence boundary: field videos demonstrate operating context and historical capability. They do not replace approved topology drawings, communication records, configured limits, FAT/SAT results or the signed acceptance package for the current project.

BLACK-HOLE, WHITE-HOLE AND VISUAL ADAPTATION LOGIC

How Should the System Support Driver Visual Adaptation?

Exterior Condition

Measure the relevant portal luminance and operating context from an approved location instead of using a generic daylight value.

Direction-Specific Design

Evaluate each driving direction separately because portal orientation, sunlight, geometry and traffic approach are not automatically identical.

Controlled Transition

Use approved zone curves and ramp rates so output changes are gradual, traceable and consistent with the visual-transition design.

Verified Minimum Scene

Preserve the approved minimum operating scene during sensor, network or platform abnormalities until the condition is resolved.

Engineering distinction: “adaptive” does not mean unrestricted real-time variation. It means measured inputs select from approved operating rules, limits and fallback scenes under declared authority.

APPROACH, PORTAL AND INTERIOR ZONES

How Should Tunnel Lighting Zones Be Separated?

Zone Primary Engineering Objective Items to Confirm Required Evidence
Approach Zone Establish the exterior visual and traffic conditions before the portal. Measurement position, portal orientation, design speed, weather influence and pre-detection distance. Sensor layout, calibration record, direction-specific test and data plausibility cases.
Threshold Zone Support initial adaptation when entering from a bright exterior environment. Required luminance, zone length, luminaire distribution, glare control, curve selection and minimum scene. Lighting calculation, photometry, field measurement and command-versus-state record.
Transition Zone Reduce output through an approved gradual curve instead of an abrupt change. Step or continuous dimming, ramp rate, spacing, returned states and exception handling. Timed transition test, measured output and controller feedback.
Interior Zone Maintain the approved scene for traffic, maintenance and abnormal conditions. Traffic influence, scheduled scenes, local control, circuit separation and outage behavior. Day, night, maintenance and communication-loss cases.
Exit Zone Support adaptation when leaving under project-specific exterior conditions. Direction-specific design, exterior condition, evening or night operation and separate acceptance cases. Direction-specific measurements and witnessed scene transitions.

TUNNEL LIGHTING CONTROL AND EVIDENCE CHAIN

How Is the Adaptive Control Architecture Organized?

1. Portal Luminance and Traffic Sensing

Measures exterior luminance, traffic direction, speed and operating conditions before selecting an approved portal lighting curve.

2. Zone-Curve and CCT Policy

Coordinates approach, threshold, transition, interior and exit-zone output, including approved ramp rates, minimum scenes and project-configured CCT.

3. CH-800 Edge Gateway and Cabinet

Stores approved local schedules and safety scenes, executes zone-level decisions and preserves defined operation during central-platform or WAN loss.

4. Circuit and Lamp-Level Execution

Delivers group or lamp-level dimming commands, verifies actual operating states and reports circuit, driver, communication and lamp exceptions.

5. Returned-State Records and Manual Authority

Records commands, actual field states, alarms, timestamps and user actions while preserving approved manual override and recovery authority.

Authority requirement: each automatic action needs a declared input, valid range, confirmation time, permitted output, ramp rate, timeout, fallback, returned state, exception path and manual authority.

DAY, NIGHT, WEATHER AND OPERATING SCENARIOS

Which Scenarios Need Separate Rules and Acceptance Cases?

Scenario Primary Inputs Control Objective Acceptance Focus
Bright Sunny Portal Exterior luminance, direction, traffic and equipment status. Select an approved higher portal curve while preserving glare and ramp limits. Threshold output, transition timing, returned states and manual authority.
Cloudy or Rapidly Changing Light Validated luminance trend and confirmation time. Avoid unnecessary repeated scene changes and unstable dimming. Hysteresis, confirmation time and no uncontrolled oscillation.
Rain, Fog or Snow Weather input, visibility context and project-approved CCT policy. Apply the approved scene and CCT only within the selected luminaire and owner policy. CCT range, output, transition behavior and fallback.
Night Operation Time, exterior condition, traffic and owner schedule. Maintain the verified night scene without copying daytime portal logic. Minimum scene, traffic influence and energy records.
Maintenance Mode Authorized operator command and work-zone information. Preserve local manual authority and clearly separate maintenance scenes from automatic operation. Permissions, status indication, timeout and return to normal operation.
Platform or WAN Loss Local schedules, last approved configuration and field states. Continue approved local operation and buffer records for later reconciliation. Offline duration, state continuity, timestamps and controlled synchronization.

MEASUREMENT, FEEDBACK AND RECONCILIATION

Which States Must the Owner See and Compare?

Portal Sensors

Current value, validity, calibration status, stale-data condition and selected fallback.

Traffic Inputs

Direction, speed or traffic state, confidence, timeout and permitted influence on scenes.

Grid and Cabinet

Supply events, meter data, cabinet status, gateway state and local-control mode where included.

Circuits

Switching, dimming, load, abnormal condition and unresolved circuit alarm.

Lamps and Drivers

Commanded level, returned state, communication, driver or sensor data supported by the selected controller.

Operator Actions

User identity, command source, timestamp, approved range, manual override and recovery result.

State-feedback requirement: sending a command is not proof of execution. Acceptance should compare the requested action with sensor, cabinet, circuit and lamp states, timestamps, unresolved exceptions and the restored operating condition.

COMMUNICATION ROUTES AND EDGE CONTINUITY

How Should Communication Support Tunnel Lighting without Becoming a Single Failure Point?

OFDM PLC

Can use suitable power conductors for command and feedback where feeder topology and measured electrical noise support the selected design.

LoRA

Can support selected wireless links where path, antenna position, obstruction, local spectrum rules and owner network policy are confirmed.

Cellular or Ethernet

Can connect approved edge or central routes where coverage, cybersecurity, ownership, recurring service and recovery responsibilities are defined.

Local Edge Operation

Approved schedules and safety scenes remain inside clearly defined zones so central connectivity is not required for every field action.

Communication boundary: route selection follows the site survey, feeder condition, distance, obstruction, network policy and witnessed recovery test. No single route is presented as universally suitable.

DEPLOYMENT ROUTES AND REQUIRED PROOF

Which Route Fits the Existing Assets and Project Risk?

Deployment Route Project Fit Required Proof
New Tunnel Design sensing, zones, cabinet and circuit boundaries, communication, local fallback and acceptance as one coordinated system. Design calculation, cabinet and controller FAT, simulated input tests, field calibration and complete SAT.
Existing Tunnel Retrofit Retain qualified cabinets, circuits, luminaires or drivers only after survey and representative compatibility testing. Asset survey, electrical and communication records, pilot, rollback method and witnessed recovery.
Long Tunnel or Tunnel Cluster Segment control and communication into defined edge zones to limit failure propagation and preserve local operation. Zone map, gateway and cabinet failure tests, route-quality records and offline-duration verification.
Bridge-Tunnel Corridor Use one management platform while preserving separate rules for roadway, portal, transition and tunnel-interior functions. Separate scene ownership, circuit boundaries, sensor cases and road/tunnel SAT records.

FAILURE STATES, SAFE FALLBACK AND RECOVERY

Which Abnormal Conditions Must Be Witnessed?

Condition Required Control Behavior Witness Method
Portal Sensor Error Reject stale, missing or implausible values and apply the approved conservative scene while reporting the exception. Inject missing, stale and out-of-range inputs and confirm alarm, fallback and recovery.
Central Platform or WAN Loss Continue approved local schedules, zone curves and manual authority. Buffer records for controlled synchronization after communication is restored. Disconnect the platform or WAN and verify local operation, event retention and reconciliation.
Abrupt Input Change Apply approved confirmation times, ramp rates and transition limits instead of an uncontrolled output jump. Change exterior luminance and traffic inputs under representative cases.
Communication Degradation Report route quality, preserve local operation and avoid interpreting missing feedback as a successful command. Introduce representative packet loss, feeder noise or route interruption.
Gateway Restart Restore the approved configuration and local authority without uncontrolled lighting-state changes. Restart a representative gateway under load and confirm zone state and field feedback.
Returned-State Mismatch Keep the requested command separate from the actual circuit or lamp state and report unresolved exceptions. Force a representative circuit or lamp to remain in the wrong state.
Configuration Conflict after Recovery Apply declared authority, timestamp and command-expiry rules without replaying obsolete commands. Create different central and field states before reconnection and witness reconciliation.

SURVEY, PILOT, FAT, SAT AND OWNER HANDOVER

How Should the Project Move to Accepted Operation?

1 · Inputs

Define geometry, zones, design speed, sensing, curves, CCT, authority, alarms, fallback and interfaces.

2 · Survey

Record portal orientation, pavement, luminaires, cabinets, circuits, drivers, sensors, communication and environmental conditions.

3 · Pilot

Use a representative portal and tunnel section to test the functions carrying the highest project uncertainty and confirm the rollback route.

4 · FAT

Verify configuration, simulated sensor inputs, zone curves, dimming ramps, failure cases, permissions, records, backups and data export.

5 · SAT

Calibrate field sensing, compare commanded and actual states, witness day, night and abnormal cases, and confirm local operation and recovery.

6 · Handover

Deliver owner credentials, zone settings, calibration records, configurations, permissions, spares and tested restoration procedures.

Scale authorization: proceed beyond the representative pilot only after exceptions are closed or formally accepted and the owner approves the FAT/SAT evidence format.

EVIDENCE INDEX FOR PROCUREMENT AND ACCEPTANCE

Which Records Should Support Technical Approval?

Topology and Zone Drawings

Direction, portal, zones, cabinets, circuits, gateways, sensors and control boundaries.

Lighting and Optical Basis

Project calculation, photometry, glare review, target values and direction-specific assumptions.

Sensor and Calibration Records

Location, orientation, range, valid-data rules, calibration, stale-data handling and fallback values.

Configuration and Permission Records

Zone curves, ramp rates, CCT, minimum scenes, roles, manual authority and change history.

Communication Evidence

Route map, feeder or radio conditions, retries, route quality, offline duration and recovery results.

FAT Records

Simulated inputs, command outputs, returned states, failure cases, backups and data export.

SAT Records

Field measurements, day and night cases, direction-specific transitions, alarms and restored operation.

Owner Handover Package

Credentials, backups, calibration data, settings, spares, support responsibilities and tested restoration procedures.

TECHNICAL VALUES, CONDITIONS AND EVIDENCE LIMITS

Which Parameters Must Be Fixed before Procurement Approval?

Engineering Item Required Boundary or Evidence
Exterior Luminance Define sensor position, orientation, field of view, calibration, valid range, stale-data timeout and fallback value.
Tunnel Zones Define approach, threshold, transition, interior and exit boundaries separately for each driving direction.
Lighting Curves Fix targets, dimming steps or continuous curves, ramp rates, minimum scenes and confirmation times.
Adaptive CCT Use the project-configured 2700K–6000K range only where the selected luminaires, control gear, visual design and owner policy support it.
Traffic Inputs Define detector type, coverage, direction, speed range, confidence rules, timeout and permitted influence on scenes.
Control Response Define the start and end point for every response-time claim and test the complete sensor-to-field-lighting path.
Offline Operation Approved local schedules and safety scenes should continue during central-platform or WAN loss. Buffered records should synchronize in a controlled manner after communication is restored.
Manual Authority Separate owner, operator, maintenance and supplier permissions, including timeout and return-to-automatic rules.
Interfaces Configure interfaces according to local regulations, owner requirements and third-party responsibilities; no universal protocol package is implied.
Acceptance Require direction-specific FAT/SAT cases, field measurements, commanded-versus-returned states and a designated approval authority.

OWNER, EPC AND PROCUREMENT DECISIONS

What Must Be Confirmed before Tender Award?

Which Portal Conditions Trigger Each Approved Curve?

Define exterior luminance thresholds, traffic conditions, weather inputs, confirmation times and fallback values for every approved zone curve.

What Remains Operational during WAN or Server Loss?

Approved local schedules, safety scenes, cabinet control and manual authority should continue within clearly defined tunnel zones.

Who May Change Zone Curves, CCT and Fallback Scenes?

Separate owner, operator, maintenance and supplier permissions, and retain traceable records for every approved configuration change.

Which Measurements Prove Visual Continuity at Acceptance?

Verify portal luminance, zone output, transition time, minimum scene, CCT behavior and actual field states under representative day, night and weather conditions.

How Are the Two Driving Directions Separated?

Use direction-specific sensors, zone definitions, curves, circuits and FAT/SAT cases where portal orientation and operating conditions differ.

How Can the Owner Restore the System Years Later?

Require owner-held credentials, configuration backups, calibration records, compatible spares, restore instructions and a witnessed recovery exercise.

Start with Tunnel Geometry, Portal Conditions and Acceptance Boundaries

Send the tunnel layout, driving directions, design speed, portal orientation, existing lighting, cabinet and circuit topology, sensing requirements, communication conditions and required FAT/SAT evidence.

Security-Sensitive Infrastructure Readiness

Owner-Controlled Deployment Readiness

Adaptive tunnel portal lighting can be engineered for municipal, transportation, industrial and security-sensitive infrastructure where the owner needs controlled hosting, defined access roles and clear responsibility for every operating record.

Deployment boundary

Define whether portal luminance zones, traffic sensing, dimming curves and safe fallback scenes connect to cloud, private server or on-premises operation.

Access boundary

Separate operator, maintainer, integrator and owner-side approval roles before commissioning.

Architecture Boundary

What Must Be Defined before System Pricing?

A credible adaptive tunnel portal lighting proposal should define the control layer, communication route, cabinet or gateway responsibility, naming method, operating policy and acceptance evidence before price comparison begins.

Control layer

Map how portal luminance zones, traffic sensing, dimming curves and safe fallback scenes are commanded, monitored and recovered.

Evidence layer

Keep black-hole and white-hole mitigation measurable through approved records, not brochure claims.

Operations Center

How Should the Owner View the Network?

The owner view should group adaptive tunnel portal lighting by project, route, area, cabinet, gateway, pole or luminaire identity so alarms, dimming plans, maintenance status and handover records remain understandable across the lifecycle.

Communications

Gateway, Cabinet and Field Communication Design

Communication design should match the actual field layout. PLC, LoRA, NB-IoT, CAT-1, Ethernet or fiber routes may be selected by distance, cabinet position, interference risk, cellular coverage, ownership policy and maintenance responsibility.

Data Ownership

Owner Data, Interface and Hosting Control

Adaptive tunnel portal lighting should preserve approved point names, alarm meanings, operating permissions, API responsibilities and exportable handover records. Interface labels are not enough; the project must define what data is exchanged and who is responsible for it.

Failure Verification

Failure-Mode Verification before Approval

The acceptance plan should witness how adaptive tunnel portal lighting behaves during communication loss, gateway restart, server isolation, sensor disagreement, abnormal command, maintenance override and recovery. The safe state must be visible to the owner.

FAT/SAT

Factory Test and Site Commissioning

Factory Test and Site Commissioning should connect equipment configuration with field results. For adaptive tunnel portal lighting, the record should show selected devices, approved parameters, tested exceptions, witnessed results and final accepted operating condition.

Acceptance Evidence

What Evidence Should Be Accepted?

Every acceptance record should identify trigger, expected state, observed state, timestamp, responsible witness, abnormal result, corrective action and final accepted condition for black-hole and white-hole mitigation.

Migration

Retrofit, Coexistence and Phased Rollout

If the project upgrades an existing site, adaptive tunnel portal lighting should support phased rollout, coexistence with retained equipment, cabinet-by-cabinet migration, temporary operation rules and rollback planning until the owner accepts the final state.

Maintenance

Maintenance Workflow and Responsibility Records

Maintenance should convert alarms into work orders, isolate real field issues from communication exceptions, record corrective action and preserve service responsibility. This is essential when portal luminance zones, traffic sensing, dimming curves and safe fallback scenes are distributed across many sites or road sections.

Energy Evidence

Energy and Performance Claim Boundary

Any saving, autonomy or performance claim for adaptive tunnel portal lighting should state the baseline, measurement boundary, operating conditions, calculation method, exception rules and verification period. A dashboard alone does not prove the result.

Interoperability

Interoperability Must Be Witnessed

Interoperability means the approved points can be exchanged, their meaning is preserved, exceptions are handled and responsibility remains visible. For adaptive tunnel portal lighting, this should be tested with the selected owner platform, not assumed from a logo.

Cybersecurity

Access, Hosting and Closed-Network Options

Security-sensitive projects may require private-server hosting, local command-center operation, controlled remote access, audit records and closed-network deployment. These options should be defined by project requirement and owner-side policy.

Lifecycle Handover

Lifecycle Handover Records

Final handover should include asset identity, approved settings, communication route, alarm list, maintenance procedure, spare-parts responsibility, software version, training records and acceptance evidence for black-hole and white-hole mitigation.

Tender Response

Tender Response Risk Reduction

A strong tender response for adaptive tunnel portal lighting makes boundaries visible before commercial comparison: scope, responsibilities, interfaces, exceptions, tests, records, lifecycle support and owner-controlled deployment route.

Strategic Partner-Branded Technology Support

Strategic Partner-Branded Technology Support

STSYSTEMPLC supports qualified long-term strategic partners with partner-branded solution packaging, technical documentation, integration support and owner-controlled deployment options for government, transportation, energy, industrial and security-sensitive infrastructure projects.

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will get back to you as soon as possible.
Related Products
CH CB001
Intelligent Cabinet is a key control solution for the Smart City LED Street Lighting Projects. It will be synchronously controlling and monitoring the grid and street lighting at one time, widely linkage to the third party devices such as energy meter, three-phase current sensor, over voltage protector, illuminance sensor, and motion sensor etc. You can monitor and control all the streetlight cabinets in any part of the world as long as there is Internet. By connecting with the motion sensor and daylight intensity detect sensor, it will provide a perfect solution and seamless for the intelligent lighting control management system on the effective energy asset management in city roads, expressways, tunnels,warehouses, factories, buildings, substations,airports lighting projects. The 3rd party sensor linkage options. Key Element of Centralized Controller PDF file can be DOWNLOAD FOLLOWING:
CH STS100
Key Features: 1. Die-casting and Extruded aluminum profile Mold for Modern assembly line appearance. 2. Dual Colors between Cool White and Warm White/Nature White design to meet abnormal weather conditions: heavy snowing area, serios fog & rains , automatically changing the CCT from 4500K/6000K to 2700K ...... by the intelligent sensors when detecting of dense fog, rainstorm or snowing. 3. Intelligent street lighting system is a core element for the smart city platform, 4. 80% of Max. power saving than traditional high pressure sodium lamps
CH STSLR100S
Key Features: 1. Die-casting and Extruded aluminum profile Mold for Modern assembly line appearance. 2. Dual Colors between Cool White and Warm White/Nature White design to meet abnormal weather conditions: heavy snowing area, serios fog & rains , automatically changing the CCT from 4500K/6000K to 2700K ...... by the intelligent sensors when detecting of dense fog, rainstorm or snowing. 3. Intelligent street lighting system is a core element for the smart city platform, 4. 80% of Max. power saving than traditional high pressure sodium lamps
CH PG002
The intelligent lighting control system of the municipal pipe gallery is independently developed by our company. Aiming at the lighting environment of the urban underground pipe gallery, the lighting of these areas can be controlled by manual temporary intervention or automatic operation through the server, workstations at all levels, on-site touch control screens or handheld devices. Status, data collection and monitoring of the equipment in the area, and at the same time realize the personnel positioning, SOS alarm, abnormal temperature change alarm and harmful gas abnormal alarm.
CH GDSWL60W
Key Features: 1. Die-casting and Extruded aluminum profile Mold for Modern assembly line appearance. 2. Dual Colors between Cool White and Warm White/Nature White design to meet abnormal weather conditions: heavy snowing area, serios fog & rains , automatically changing the CCT from 4500K/6000K to 2700K ...... by the intelligent sensors when detecting of dense fog, rainstorm or snowing. 3. Intelligent street lighting system is a core element for the smart city platform, 4. 80% of Max. power saving than traditional high pressure sodium lamps
CH STDUCREE300A
Super high output at 200lm/W, 180lm/W, 160lm/W, 130lm/W optional to meet different Budgets. High-quality Led street light from SOWIN ,contact us for the reasonable price from leading led street light manufacturer in China. All of them adopts world famous brand leaders led chips like Phillips,Osram and Cree, and professional roads lighting optical lens with high efficiency,and uniform light. Power range from 30W to 300W, which suitable for any height poles, and kinds of roads lighting.
CH TLDUCCT100W
6000K ~ 2700K CCT Automatic - Changing at Rainy / Snowing / Foggy Time. 93km IoT highway roadway light in Shen Zhen standing for World Smartest modern lighting projects.     Smart Tunnel Light and LED roadway lights provide the incredibly efficient-offering super high output at 200lm/W, 175lm/W &160lm/W 130lm/W optional to meet different Budgets High-quality Led street light from SOWIN, contact us for the reasonable price from leading led street light manufacturer in China. All of them adopts world famous brand leaders led chips like Phillips,Osram and Cree, and professional roads lighting optical lens with high efficiency,and uniform light. Power range from 30W to 300W, which suitable for any height poles, and kinds of roads lighting.           Dual Colors Temperature Solutions: 2700K ~ 4500K/6000K Automatic Changing by Weather Sensor    Our Dual Colors Temperature LED street lighting will be perfect solution for the heavy snowing area, serios fog & rains roads, they will be automatically changing the CCT from( from example 4500/6000k to 2700k) nature white-Daylight/cool white to Warm white colors by the intelligent sensors when detecting of dense fog, rainstorm or snowing.     Moreover our Intelligent street lighting system is a core element for the smart city platform, with maximum power saving rate up to 80% than traditional high pressure sodium lamps and the metal halide lamps by dimming on-demand lighting brightness to the whole city, and at least more of 30% power saving than normal led street lamps without the smart lighting control & management system, and extend the lamps service lifetime dramatically by dimming to minimum safety illumination at midnight.   Smart Street Light System      IoT LED Street Lighting enables Outdoor Lighting Maintain and repair synchronously to provide safe access to all road users, it is a key control solution for the Smart City LED Street Lighting Projects, which will be synchronously controlling and monitoring the grid and street lighting at one time, widely linkage to the third party devices such as energy meter, three-phase current sensor, over voltage protector, illuminance sensor, and motion sensor etc. You can monitor and control all the streetlight cabinets in any part of the world as long as there is Internet.   By connecting with the motion sensor and daylight intensity detect sensor, it will provide a perfect solution and seamless for the intelligent lighting control management system on the effective energy asset management in city roads, expressways, tunnels,warehouses, factories, buildings, substations,airports lighting projects. The 3rd party sensor linkage options.     Both of PLC - Power line communica, LoRa, RS485 and Loop Controlling ect. solutions to fit any different Budget.       Ambient Sensor Connected the Outdoor Street Luminaires      The CH-C202 Environmental Light Monitoring Equipment is independently researched and developed by our company. According to the Roads/Tunnel environment, it cooperates with the intelligent lighting centralized controller to automatically control the illuminance of the lamps according to the changing of environmental brightness, to achieve the purpose of intelligent management and control.    Traditional municipal street lighting, street lamp tunnel lighting, industrial lighting such as factory&warehouse lighting Switches Controlling Modes are generally divided into Loop Controlling, Sunrise & Sunset Controlling, the corresponding fixtures Loop Controlling in different time periods. Although the controlling is mature and widely used, there are still many problems, such as: it can’t be automatically adjusted Brightness at rainy, sandy weather, the adjustment range is fixed (only loop switch); moreover, it is impossible to know the environmental brightness of the project site in time. In response to these problems, our company launched this Luminance Collection Equipment. which integrates brightness collection, data processing, and data communication.    The device adopts GPRS communication mode, which can report the collected brightness data to the server directly.   Motion Sensor adapt the Seamless Connecting LED Street Lighting      The Motion Sensor aims at the using environment of street lighting, tunnels and factories etc., through the moving detection of vehicles, people or objects, the lighting fixtures are automatically controlled according to programming to realize intelligent lighting control.     Traditional street lightings,  tunnels, factori...
G01
.corridor-summary{box-sizing:border-box!important;display:grid!important;grid-template-rows:minmax(0,1fr) auto!important;width:100%!important;height:auto!important;min-height:0!important;aspect-ratio:auto!important;margin:0!important;padding:0!important;overflow:hidden!important;color:#173f5e!important;font-family:Arial,"Helvetica Neue",Helvetica,sans-serif!important} .corridor-summary .corridor-summary__copy{grid-row:1!important;min-height:0!important;overflow:hidden!important;margin-bottom:0!important} .corridor-summary .corridor-summary__copy p{margin:0 0 9px!important;color:#28495f!important;font-size:clamp(12.8px,1.04vw,14px)!important;font-weight:400!important;line-height:1.43!important} .corridor-summary .corridor-summary__copy p:last-child{margin-bottom:8px!important} .corridor-summary .corridor-summary__copy .summary-key{font-size:inherit!important;font-weight:900!important;color:#173f5e!important;line-height:inherit!important} .corridor-summary__check{box-sizing:border-box!important;grid-row:2!important;align-self:end!important;margin:0!important;padding:10px 13px 11px!important;border:1px solid #86bfe9!important;border-left:4px solid #1688cf!important;border-radius:10px!important;background:linear-gradient(135deg,#ffffff 0%,#eef8ff 100%)!important;box-shadow:inset 0 0 0 1px rgba(255,255,255,.78)!important;color:#174b74!important} .corridor-summary__title{margin:0 0 3px!important;color:#0e598b!important;font-size:13px!important;font-weight:900!important;line-height:1.05!important;letter-spacing:1.15px!important;text-transform:uppercase!important} .corridor-summary__intro{margin:0 0 7px!important;color:#174b74!important;font-size:10.8px!important;font-weight:700!important;line-height:1.28!important} .corridor-summary__grid{display:grid!important;grid-template-columns:repeat(2,minmax(0,1fr))!important;column-gap:19px!important;row-gap:5px!important;margin:0!important;padding:0!important} .corridor-summary__item{margin:0!important;color:#174b74!important;font-size:10.5px!important;font-weight:400!important;line-height:1.31!important} .corridor-summary__item strong{color:#0f527f!important;font-weight:900!important} @media(max-width:760px){.corridor-summary{display:block!important;height:auto!important;aspect-ratio:auto!important;overflow:visible!important}.corridor-summary .corridor-summary__copy{overflow:visible!important}.corridor-summary .corridor-summary__copy p{font-size:14px!important;line-height:1.48!important;margin-bottom:10px!important}.corridor-summary__check{margin-top:14px!important}.corridor-summary__grid{grid-template-columns:1fr!important;row-gap:6px!important}.corridor-summary__item{font-size:11.3px!important;line-height:1.38!important}} .corridor-summary .corridor-summary__copy{margin-bottom:10px!important} .corridor-summary .corridor-summary__partner{box-sizing:border-box!important;display:block!important;margin:10px 0 16px!important;padding:0!important;border:0!important;background:transparent!important;color:#174b74!imp...
Get the latest offers Subscribe for our newsletter
Please read on, stay posted, subscribe, and we welcome you to tell us what you think.

click here to leave a message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will get back to you as soon as possible.

Home

Products

about

contact